Extech Instruments 1300 OWL Specifications

Browse online or download Specifications for Measuring, testing & control Extech Instruments 1300 OWL. Extech Instruments 1300 OWL Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
MicroMeter
Optical Power Meter
Operations Manual
Firmware Version 1.20e
September 15, 2003
Part Numbers: MO500, MO510, MO520Extech
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - Optical Power Meter

MicroMeterOptical Power MeterOperations ManualFirmware Version 1.20eSeptember 15, 2003 Part Numbers: MO500, MO510, MO520Extech

Page 2

Operation, cont.Stored Data MenuThe STORED DATA menu allows the user to manipulate data that is stored in the MicroMeter. - this option allows the us

Page 3 - Serial Number

3-1The whole purpose of fiber certification with the MicroMeter is to save data points using a standards-based reference point and produce professiona

Page 4 - INTRODUCTIONUNIT 1

STEP 1 - SELECT LINK1-1) Press to enter the MAIN MENU.MENU 1F1F3F1 DONEF2 DONEDONEF221F2DONEDONEDONEF1 DONE1-2) Press to SELECT LINK.1-3) At

Page 5

FIBER LINK #1NAME = FBR:00TYPE=62.5um MM-22.05dBm 850nmDATAPRINT EDITNAME SAVE________________||||wavelength as in step 2-7. Repeat steps 2-7 through

Page 6

3-44-4) Connect the MicroMeter to the PC via the download cable supplied with the meter. 4-5) Start the Reporter software on the PC.4-6) Click the

Page 7

The MicroMeter meter has a decibel(dB) range that spans 75dB. The whole purpose of your meter is to measure light energy in decibels. But what exact

Page 8

There are other decibels to consider. The decibel we previously described is”dB” is called relative. This is because it is a ratio as was explained.

Page 9

Bandwidth. The transmission capacity of a system.Buffering. 1. A protective material extruded directly on the fiber coating to protect the fiber f

Page 10 - METER FUNCTIONSUNIT 2

Equipment Room. A centralized space for telecommunications equipment that serves the occupants of the building. Equipment housed herein is considere

Page 11 - FIBER CERTIFICATIONUNIT 3

Multi-mode Fiber. A type of optical fiber that supports more than one propagating mode.Numeric Aperture (NA). The number that expresses the light-g

Page 12

Table of ContentsPreface iiWhy Use An Optical Power Meter? iiChecking the MicroMeter Firmware Version iiUnit 1 - IntroductionDescription 1-1Applicatio

Page 13

Detector Type:------------------------------- Ge (2mm)Calibrated Wavelengths:---------------------- 850, 1300/1310, 1550Measurement Range:------------

Page 14

The MicroMeter is a sensitive piece of scientific equipment. Great care should be taken when handling and cleaning it.1) Do NOT drop any piece of sci

Page 15 - APPENDICESUNIT 4

Appendix G - Optional Accessories4-8UNIT 3APPENDICESAPPENDICESUNIT 4PR600 - Mini Serial Thermal Printer with CableCB600 - Cable for PR600 PrinterLE200

Page 16 - APPENDICES

Fiber TypePassive Cable System AttenuationFiber Loss at Operating Wavelength (Distance x Fiber Loss)Connector Loss (Connector Loss x Connector Pairs)S

Page 17

UNIT 3APPENDICESAppendix I - Reference jumper setupYour test jumpers must be cleaned and inspected prior to using them for fiber link testing. You sh

Page 18

Standards organizations such as the TIA or the ISO/IEC provide performance standards that the cabling plant must adhere to in order to support high-sp

Page 19

The MicroMeter can be used for several applications. A listing of these applications and their descriptions follows:Attenuation and Loss Measurements

Page 20

2.5mm UNIVERSAL ADAPTER PORT - accepts standard 2.5mm ferrule connectors (ST, SC, FC).COMPUTER PORT - port for downloading data from the meter to a PC

Page 21

2-1Operation1) Press the button.2) After a few seconds, a screen will appear that looks like the one below, which is called Immediate Mode.ONPower

Page 22

Measurements can be taken for four different wavelengths in the MicroMeter. These wavelengths are 850, 1300/1310, and 1550nm. All wavelengths are tr

Page 23

Operation, cont.Main MenuAdvanced meter functions can be configured from the Main Menu. Options 1 through 4 are listed in a step-by-step order for ce

Page 24

Operation, cont.2-4Manual Reference Method-recommended for advanced users onlyThe Micro can be used to certify fiber links (shown in detail in the nex