Extech Instruments MN16A User's Guide Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
MN16-EU V1.4 03/12
10
Specifications
Function Range Resolution Accuracy
4V 0.001V
40V 0.01V
400V 0.1V
±(1.2% reading + 2 digits)
DC Voltage
(V DC)
600V 1V
±(1.5% reading + 2 digits)
400mV* 0.1mV
±(1.5% reading + 15 digits)
4V 0.001mV
±(1.2% reading + 3 digits)
40V 0.01V
400V 0.1V
±(1.5% reading + 3 digits)
600V 1V
±(2.0% reading + 4 digits
AC Voltage
(V AC)
(50 / 60Hz)
*400mV range is not autoranging
400μA 0.1μA ±(1.0% reading + 3 digits)
4000μA 1μA
40mA 0.01mA
400mA 0.1mA
±(1.5% reading + 3 digits)
DC Current
(A DC)
10A 0.01A
±(2.5% reading + 5 digits)
400μA 0.1μA ±(1.5% reading + 5 digits)
4000μA 1μA
40mA 0.01mA
400mA 0.1mA
±(1.8% reading + 5 digits)
AC Current
(A AC)
10A 0.01A
±(3.0% reading + 7 digits)
400Ω 0.1Ω ±(1.2% reading + 4 digits)
4kΩ 1Ω ±(1.0% reading + 2 digits)
40kΩ 0.01kΩ
400kΩ 0.1kΩ
4MΩ 0.001MΩ
±(1.2% reading + 2 digits)
Resistance
40MΩ 0.01MΩ ±(2.0% reading + 3 digits)
40nF 0.01nF
±(5.0% reading + 30 digits)
400nF 0.1nF
4μF 0.001μF
40μF 0.01μF
±(3.0% reading + 5 digits)
Capacitance
100μF 0.1μF ±(5.0% reading + 5 digits)
0.1 to 99.9%
0.1%
±(1.2% reading + 2 digits)
Duty Cycle
pulse width range: 100µs - 100ms (Frequency: 5Hz to 150kHz)
-4 to 1400°F 1°F
Temp (type-K)
-20 to 750°C 1°C
±(3.0% reading + 9°F/5°C)
(probe accuracy not included)
Page view 9
1 2 ... 5 6 7 8 9 10 11 12

Comments to this Manuals

No comments