QuickStartInstructions
MeterPower
PressthepowerbuttontoswitchthemeterON.ThedisplaywillswitchON.Ifthedisplaydoesnotswitch
ON,replacethebatteries.
Measurements
Usethesuppliedfilmreferencesandzeroreferencemetalsubstratestolearnhowthemeteroperates
beforemovingtoaprofessionalapplication.Theroundmetalsubstrateistheferrous(magnetic)substrate
andtherectangularshapedmetalsubstrateisthenonferrous(nonmagnetic)substrate.Themeter
automaticallysensesferrousornon
ferroussubstrates.
1. Placeareferencefilm(250µm,forexample)ontheround,ferroussubstrate.
2. Placethespringloadedmetersensoragainstthereferencefilm.
3. Inthesinglemodethemeterwillemitanaudibletoneindicatingthatthemeasurementhasbeen
taken.
4. Inthecontinuousmodethedisplaywillcontinuallymeasureandupdatethedisplay
5. TheLCDwillshowthereading(250µm)atthecenterofthedisplayarea.
6. Atypicaldisplaywillalsoshowthefollowing:
NO=1(readingnumberone)onthelowerleftofthe
LCD
AVG
=250µm(runningaverage)onthelowerright
DIR=DIRmodeofoperationontheupperleft
Fe=FerroussubstrateontheupperrightoftheLCD

Experimentwiththeremainingreferencefilmsandthesubstratebeforeusingthemeterprofessionally.
AutomaticPowerOFF
Inordertoconservebatterylife,themeterwillautomaticallyturnoffafterapproximately3minutes.To
defeatthisfeatureusetheprogrammingmenudetailedinthenextsection(menuparameterAUTOPOWER
OFFunderOPTIONS).
LCDBacklightButton
TheLCDisequippedwithbacklightingforeasierviewing,especiallyindimlylitareas.Pressthebacklight
buttontoturnthebacklighton.Pressagaintoturnthebacklightoff.Toenable/disabletheLCDbacklighting,
usetheBACKLIGHTparameterunderOPTIONSintheprogrammingmenu.
FactoryDefaultReset
Torestorethemetertoitsoriginalfactorydefaultsettings:
1. TurnthemeterOFF.
2. PressandholdtheZERObuttonwhileswitchingthemeterON.
3. Whenthemeterpowersup,thedisplaywillpromptforaYESorNO.
4. PresstheSETbuttonforYESorthe
CANCELbuttonforNO.
5. Notethatalldatainallmemorylocationswillbeerased,inadditiontostatistics,calibrationvalues,
andalarmlimits.