User’s Guide
MultiPro™ Digital MultiMeter Series
With PC Interface
Models:
MP510A
MP530A
00 1 21 3 42 84 9 1055637
A
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - 00 1 21 3 42 84 9 1055637

User’s Guide MultiPro™ Digital MultiMeter Series With PC Interface Models: MP510A MP530A 00 1 21 3 42 84 9 1055637A

Page 2

10μA, mA, and A Current functions Default at DC. Press SELECT button momentarily to select AC. *Note: When measuring a 3-phase system, special attent

Page 3

1150ms MAX/MIN at fast 20/s measurement mode (Model MP530 only) Press the MAX/MIN button momentarily to activate MAX/MIN recording mode. The LCD annu

Page 4

12Backlighted display Press the SELECT button for 1 second or more to turn on or off the display backlight function. The backlight will also be tu

Page 5

13 Relative mode (Model MP530 only) Relative zero allows any reading to be stored as a reference value and all following reading to be reference to

Page 6

14Auto Power Off (APO) The Auto Power Off (APO) mode turns the meter off automatically to extend battery life after approximately 17 minutes of no a

Page 7 - Reverse Bias

15Trouble Shooting If the instrument fails to operate, check battery, fuses, leads, etc., and replace as necessary. Double check operating procedure

Page 8

16 (6) SPECIFICATIONS DC VOLTAGE RANGE Accuracy 50.00 mV 0.12% + 2d 500.0 mV 0.06% + 2d 5.000V, 50.00V, 500.0V, 1000V 0.08% + 2d NMRR: >60dB @

Page 9

17AC CURRENT RANGE Accuracy Burden Voltage 50 / 60Hz 500.0μA, 5000μA 0.6%+3d 0.15mV/μA 50.00mA, 500.0mA 0.6%+3d 3.3mV/mA 5.000A, 10.00A* 0.6%+3d

Page 10

18TEMPERATURE (MP530 ONLY) RANGE Accuracy -50°C TO 1000°C 0.3% + 3d -58°F TO 1832°F 0.3% + 6d FREQUENCY Function Sensitivity (ACrms) Range mV 300

Page 11

19Storage Temperature: -4° to 140°F (-20 to 60oC) Relative Humidity: Max 80% up to 87ºF (31ºC) decreasing linearly to 50% at 113ºF(45ºC): <80%

Page 12

21) SAFETY Terms in this manual WARNING identifies conditions and actions that could result in serious injury or even death to the user. CAUTION id

Page 13

20Support line (781) 890-7440 Technical Support: Extension 200; E-mail: [email protected] Repair & Returns: Extension 210; E-mail: repair@extech

Page 14

3WARNING To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. To avoid electrical shock hazard, observe the

Page 15

43) PRODUCT DESCRIPTION Panel Illustration 00 1 21 3 42 84 9 1055637A1234567 1) 5000 count LCD display 2) Push-buttons for special functions &a

Page 16 - (6) SPECIFICATIONS

5Analog bar-graph The analog bar graph provides a visual indication of measurement like a traditional analog meter needle. It is excellent for detect

Page 17

6CMRR (Common Mode Rejection Ratio) Common mode voltage is voltage present on both the COM and VOLTAGE input terminals of a DMM, with respect to gro

Page 18

7 Capacitance, Diode test function Default at . Press SELECT button momentarily to select Diode test function. CAUTION Discharge capacitors bef

Page 19

8Temperature function (Model MP530 only) Press SELECT button momentarily to toggle between °C and °F readings, and the new setting will be saved auto

Page 20 - WARRANTY

9CAUTION Using resistance and continuity function in a live circuit will produce false results and may damage the instrument. In many cases the suspe